Chapter5.Function parameter
26
Frequency set by F0.03 master
frequency setting source
Auxiliary frequency
display
Frequency set by F0.04 auxiliary
frequency setting source
Observe the set command torque
under the torque control mode
Display run, standby and other
statuses
1.G type (constant torque load
type)
AI1 voltage before
correction
Input voltage value before AI1
linear correction
AI2 voltage before
correction
Input voltage value before AI2
linear correction
Panel potentiometer
voltage before
correction
Panel potentiometer voltage
before linear correction
motor temperature
inspection value
PT100 inspect motor temperature
value
5-1-2.F0 Group -Basic function group
0:Vector control without PG
Refers to the open-loop vector control for high-performance control applications
typically , only one inverter to drive a motor.
1: Reserved
2:V/F control
Suitable for less precision control applications, such as fan and pump loads. Can
be used for an inverter drives several motors occasions.
Note: Vector Control mode, the difference power between inverter and motor