Chapter5.Function parameter
59
Power-on time of
the third fault
Current power-on time of the last fault
Running time of
the third fault
Current running time of the last fault
Frequency of the
second fault
Frequency of the last fault
Current of the
second fault
Current of the last fault
Bus voltage of the
second fault
Bus voltage of the last fault
Input terminal
status of the
second fault
Input terminal status of the last fault, the
order is:
BIT9 BIT8 BIT7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0
DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 DI9 DI0
When the input terminal is ON, the
corresponding binary bits is 1, OFF is 0, all
DI status is converted to the decimal number
for display.
Output terminal
status of the
second fault
Output terminal status of the last fault, the
order is:
When the output terminal is ON, the
corresponding binary bits is 1, OFF is 0, all
DI status is converted to the decimal number
for display.
Power-on time of
the second fault
Current power-on time of the last fault
Running time of
the second fault
Current running time of the last fault
Frequency of the
first fault
Frequency of the last fault
Current of the
first fault
Current of the last fault
Bus voltage of the last fault