Chapter8.Installation and Spare Circuit
73
bipolar input
2.Input impedance: 2.4kΩ
3.Voltage range with level input: 9V to 30V
4
. Below 11KW: (DI1 to DI6)drive manner
is controlled by J5, when external power
supply is used to drive, please unplug J5
jumpers ,
5
. Above 11KW: (DI1 to DI4)drive manner
is controlled by J6, (DI5 to DI8)drive
manner is controlled by J5, when
external power supply is used to drive,
please unplug J5 jumpers ,
High-speed
pulse input
terminals
Except the function of DI1 to DI4,DI6 to
DI8,DI5 can also be used as high-speed
pulse input channels.Maximum input
frequency: 100kHz
The selected J2 jumper on control panel
determines voltage or current output.
Output voltage range: 0V to 10V , output
current range: 0mA to 20mA
The selected J1 jumper on control panel
determines voltage or current output.
Output voltage range: 0V to 10V , output
current range: 0mA to 20mA
Opto-coupler isolation, bipolar open
collector output
Output voltage range: 0V to 24V , output
current range: 0mA to 50mA
Subject to function code(F2.00)"SPB
terminal output mode selection"
As a high-speed pulse output, the highest
frequency up to 100kHz;
Contactor drive capacity: normally closed
contact 5A/AC 250V,normally open
contact 3 A/AC 250V,1A/ DC 30V, COSø
= 0.4.
Normally
closed
terminals