Select
inverter control command input channel. Inverter control commands include:
start, stop, forward, reverse and jog, etc.
0:
keyboard control
("LOCAL / REMOTE" lights out);
Operate command control by using RUN, STOP/RESET Keys on the operation panel.
1:
terminal block control
("LOCAL / REMOTE" lights up);
Operate command control by using multi-function input terminals FWD, REV or FJOG.
2:
communication command control
("LOCAL / REMOTE" flashes)
Gives the run command from the host computer through the means of communication.
Select this option, the optional communication card(Modbus card) is required .
3.keyboard+communication command control
Operation panel and communication command control.
4.keyboard+terminal block+communication command control
Operation panel、terminal block and communication command control.
Define the combination of 3 operation command channels and 9 frequency reference
channels for easily synchronously switching.
The principle for above frequency source reference channel is same as frequency source
master setting selection F0.03, please see the description of F0.03 function code. The
different running command channel can be bundled with the same frequency reference