0: linear V/F
Suitable for ordinary constant torque load.
1: multi-point V/F
Suitable for dehydrator, centrifuge and other special loads any V/F relationship curves
can be obtained by setting parameters F4.03 to F4.08.
2: square V/F
Suitable for fans, pumps and centrifugal loads.
3 to 8: V/F relationship curve between linear V/F and square V/F.
10:VF separate completely mode. In this mode, the output frequency and output voltage
is separated completely, no any relationship at all, the output frequency controlled by
frequency source setting , but output voltage determined by F4.12 setting.(V/F separate
voltage supply source )
V/F separated completely mode can suitable for in inductive heating, inverter power
supply, torque motor, etc applications.
11: V/F semi-separate mode.
V is proportional to F in this mode, but the proportional relationship can be set by F4.12
parameters, furthermore, the V and F proportion also relate to rated voltage of motor and
rated frequency in b0 group.
Assume that input voltage source is X ( X value range from 0~100%), the output
voltage V and output frequency F proportion relationship can be defined as : V/F=2*X*
(rated voltage of motor)/(rated frequency of motor)