Chapter 5 Function parameter
131
Under the parameter selection menu, The subtract function keysadjust the parameter
selection
Under the parameter modify menu, the subtract function keys adjust the parameter
value.
Multifunction key is defined free stop key.
The key is effective under Parameter selection monitor menu, the inverter is free
stop. After free stop , no startup command , after 1S, it is allowed restart .
2:Multifunction key is defined as FWD Forward funning key.
Under monitor menu, the key is effective under Parameter selection menu, the
inverter is forward running.
3:Multifunction key is defined as FEV reverse running function key.
The key is effective under Parameter selection monitor menu, the inverter is forward
running.
4: Multifunction key is defined as Forward Jog running key.
The key is effective under Parameter selection monitor menu, the inverter is forward
jog running.
5: Multifunction key is defined as Reverse Jog running key.
The key is effective under Parameter selection monitor menu, the inverter is reverse
jog running.
6: Multifunction key is defined as UP function key.
The key is effective at any time, the control way is same as terminal control UP.
7Multifunction key is defined as DOWN function key.
The key is effective at any time , the control way is same as terminal control UP.
Note: “Superscript
3
”Means software version is above C3.00 with MCU keyboard
has the function.
5-2-9.Auxiliary function: F7.00-F7.54
Code
Parameter name
Setting range
Factory
setting
Change
Limit
F7.00
Jog running frequency
0.00Hz to F0.19
(maximum frequency)
6
.
00Hz
F7.01
Jog acceleration time
0.0s to 6500.0s
5.0s
F7.02
Jog deceleration time
0.0s to 6500.0s
5.0s
Defined the inverter's reference frequency and ac/deceleration time when jogging
In operation of Jog, the startup mode is fixed as direct startup mode (F3.00 = 0), the
shutdown mode is fixed as deceleration parking mode (F3.07 = 0).
F7.03
Jog priority
Invalid
0
0
Valid
1
This parameter is used to set whether the priority of jog function is active or
not..When it is set to active, if the jog command is received by inverter in operation, the
inverter will change to jog running status.
F7.04
Jump frequency 1
0.00Hz to
F0.19(maximum
frequency)
0.00Hz
F7.05
Jump frequency 2
0.00Hz to
F0.19(maximum
frequency)
0.00Hz