EasyManua.ls Logo

Powtran PI9000 series - Page 175

Powtran PI9000 series
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Function parameter
169
No.
Code
Parameter name
Setting range
Factory
setting
Change
limit
509.
E3.12
Virtual VDO2
output function
selection
With the physical internal
sub DIx
0
0
See F2 group physical DO
output option
1to40
510.
E3.13
Virtual VDO3
output function
selection
With the physical internal
sub DIx
0
0
See F2 group physical DO
output option
1to40
511.
E3.14
Virtual VDO4
output function
selection
With the physical internal
sub DIx
0
0
See F2 group physical DO
output option
1to40
512.
E3.15
Virtual VDO5
output function
selection
With the physical internal
sub DIx
0
0
See F2 group physical DO
output option
1to40
513.
E3.16
VDO output
terminal effective
status selection
Units digit:VDO1
0:Positive logic
1:Negative logic
Tens digit: VDO2(0 to 1,same as
above)
Hundreds digit:VDO3(0 to 1,same
as above)
Thousands digit:VDO4(0 to 1,same
as above)
Tens of thousands digit:VDO50
to 1,same as above
00000
514.
E3.17
VDO1 output
delay time
0.0s to 3600.0s
0.0s
515.
E3.18
VDO2 output
delay time
0.0s to 3600.0s
0.0s

Table of Contents