Chapter 5 Function parameter
176
12: upload parameter to keyboard storage area 2
3
Upload the parameters of the inverter to the keyboard storage area 2
3
21: download the parameters from keyboard storage 1 area to the storage system
3
Download the parameters from keyboard storage 1 to inverter
22:download the parameters from keyboard storage 2 area to the storage system
3
Download the parameters from keyboard storage 2 to inverter
Note:
“Superscript
3
”means software version of C3.00 and above with MCU keyboard
have such function.
When y0.01 is set to one any non-zero number, the password protection will take
effect. You enter the menu for the next time, you must enter the password correctly,
otherwise can not view and modify the function parameters, please keep in mind the set
user password.
When y0 .01 is set to 0, the set user password will be cleared, the password protection
function is invalid.
Function
parameters
display
properties
d group
display
selection
E group
display
selection
b group
display
selection
y group
display
selection
L group
display
selection
Units digit:
Reserved
Tens digit :User‟s change
parameter display selection