Chapter 5 Function parameter
37
No.
Code
Parameter name
Setting range
Factory
setting
Reference
page
19.
d0.19
Feedback
speed(unit:0.1Hz)
PG feedback speed, to an
accuracy of 0.1hz
0.1Hz
86
20.
d0.20
Remaining run
time
Remaining run time
display, it is for timing run
control
0.1Min
86
21.
d0.21
Linear speed
Linear speed calculated
from angular speed and
diameter is used for
controlling constant tension
and constant linear speed.
1m/Min
86
22.
d0.22
Current power-on
time
Total time of current
inverter power-on
Min
86
23.
d0.23
Current run time
Total time of current
inverter run
0.1Min
86
24.
d0.24
High-speed pulse
input frequency
High-speed pulse input
frequency display, unit:
1Hz
1Hz
86
25.
d0.25
Communication set
value
Frequency, torque or other
command values set by
communication port
0.01%
86
26.
d0.26
Encoder feedback
speed
PG feedback speed, to an
accuracy of 0.01Hz
0.01Hz
86
27.
d0.27
Master frequency
display
Frequency set by F0.03
master frequency setting
source
0.01Hz
87
28.
d0.28
Auxiliary
frequency display
Frequency set by F0.04
auxiliary frequency setting
source
0.01Hz
87
29.
d0.29
Command torque
(%)
Observe the set command
torque under the torque
control mode
0.1%
87
30.
d0.30
Reserve
31.
d0.31
Synchro rotor
position
Synchro rotor position
angle
0.0°
87
32.
d0.32
Resolver position
Rotor position when rotary
transformer is used as a
speed feedback
-
87

Table of Contents