Chapter 5 Function parameter
44
No.
Code
Parameter name
Setting range
Factory
setting
Change
Referenc
e page
97.
F1.27
Minimum pulse input
frequency setting
-100.00% to
+100.0%
0.0%
108
98.
F1.28
Maximum pulse input
frequency
F1.26 to 100.00kHz
50.00
kHz
108
99.
F1.29
Maximum pulse input
frequency setting
-100.00% to
+100.0%
100.0%
108
100. .
F1.30
DI filter time
0.000s to 1.000s
0
.
01s
108
101.
F1.31
AI
1 filter time
0.00s to 10.00s
0.10s
108
102.
F1.32
AI2 filter time
0.00s to 10.00s
0.10s
108
103.
F1.33
Filtering time of panel
potentiometer
0.00s to 10.00s
0.10s
108
104.
F1.34
Filter time of pulse
input
0.00s to 10.00s
0.00s
108
105.
F1.35
DI terminal valid
mode selection 1
Units digit: DI1
0:
high level active
1:
low level active
Tens digit: DI2
Hundreds digit:
DI3
Thousands digit: DI4
Ten thousands digit:
DI5
00000
108
106.
F1.36
DI terminal valid
mode selection 2
Units digit: DI6
0: high level active
1: low level active
Tens digit:
DI7
Hundreds digit: DI8
Thousands digit: DI9
Ten thousands digit:
DI10
00000
109
107.
F1.37
DI1 delay time
0.0s to 3600.0s
0
.
0s
109

Table of Contents