Chapter 5 Function parameter
54
No.
Code
Parameter name
Setting range
Factory
setting
Change
Refere
nce
page
215.
F7.13
Deceleration time 4
0.0s to 6500.0s
Depends
on models
133
216.
F7.14
Switching frequency
point between
acceleration time 1 and
acceleration time 2
0.00Hz to F0.19
(maximum
frequency)
0.00Hz
133
217.
F7.15
Switching frequency
point between
deceleration time 1 and
deceleration time 2
0.00Hz to F0.19
(maximum
frequency)
0.00Hz
133
218.
F7.16
Forward/reverse rotation
deadband
0.00s to 3600.0s
0
.0
0s
133
219.
F7.17
Reverse rotation control
0:
Enable
1: Disable
0
134
220.
F7.18
Set frequency lower
than lower limit
frequency mode
0:
running at lower
limit frequency
1: stop
2: zero speed
running
0
134
221.
F7.19
Droop control
0.00Hz to 10.00Hz
0
.
00Hz
134
222.
F7.20
Setting cumulative
power-on arrival time
0h to 36000h
0h
134
223.
F7.21
Setting cumulative
running arrival time
0h to 36000h
0h
134
224.
F7.22
Start protection
selection
0: OFF
1: ON
0
135
225.
F7.23
Frequency detection
value (FDT1)
0.00Hz to
F0.19(maximum
frequency)
50.00Hz
135
226.
F7.24
Frequency detection
hysteresis value (FDT1)
0.0% to 100.0%
(FDT1 level)
5.0%
135
227.
F7.25
Frequency reaches
0.00 to 100%
(maximum
0
.
0%
135

Table of Contents