Chapter 5 Function parameter
55
No.
Code
Parameter name
Setting range
Factory
setting
Change
Refere
nce
page
detection width
frequency)
228.
F7.26
Frequency detection
value (FDT2)
0.00Hz to F0.19
(maximum
frequency)
50
.
00Hz
136
229.
F7.27
Frequency detection
hysteresis value (FDT2)
0.0% to 100.0%
(FDT2 level)
5
.
0%
136
230.
F7.28
Random arrivals
frequency detection
value 1
0.00Hz to F0.19
(maximum
frequency)
50.00Hz
136
231.
F7.29
Random arrivals
frequency detection
width 1
0.00% to 100.0%
(maximum
frequency)
0.0%
136
232.
F7.30
Random arrivals
frequency detection
value 2
0.00Hz to F0.19
(maximum
frequency)
50.00Hz
136
233.
F7.31
Random arrivals
frequency detection
width
2
0.00% to 100.0%
(maximum
frequency)
0.0%
136
234.
F7.32
Zero current detection
level
0.0% to 300.0%
(rated motor
current)
5.0%
137
235.
F7.33
Zero current detection
delay time
0.01s to 360.00s
0.10s
137
236.
F7.34
Overrun value of output
current
0.0% (not detected)
0.1% to 300.0%
(rated motor
current)
200.0%
137
237.
F7.35
Output current overrun
detection delay time
0.00s to 360.00s
0.00s
137
238.
F7.36
Random arrivals current
1
0.0% to 300.0%
(rated motor
current)
100%
138

Table of Contents