Input:
Supply voltage universal ............................. 21.6...253 VAC
50...60 Hz
19.2...300 VDC
Internal consumption .................................. 2 W (2 channels)
Max. consumption....................................... 4 W (2 channels)
Outputs:
Output voltage ............................................. > 18 VDC at 20 mA
Output current per channel (max.) .............. 28 mA
Relay outputs:
ON within limit ............................................. > 3.8...< 20.5 mA
Vmax ........................................................... 250 VRMS
Imax ............................................................. 2 ARMS
Max. AC output .......................................... 100 VA
Max. load at 24 VDC ................................... 1 A
EEx / I.S. approval:
DEMKO 99ATEX126256 .............................. II (1) GD
[EEx ia] IIC
Applicable for zone ..................................... 0, 1, 2, 20, 21 or 22
Ex / I.S. data:
U
m
............................................................... : 250 V
U
o
................................................................ : 28 VDC
I
o
. ................................................................. : 93 mADC
P
o
................................................................ : 0.65 W
L
o
................................................................. : 3 mH
C
o
................................................................ : 0.08 µF
GOST R approval:
VNIIM & VNIIFTRI, Cert. no. ........................ See www.prelectronics.com
Observed authority requirements: Standard:
EMC 2004/108/EC ...................................... EN 61326-1
LVD 2006/95/EC .......................................... EN 61010-1
PELV/SELV ................................................... IEC 364-4-41 and EN 60742
ATEX 94/9/EC .............................................. EN 50014, EN 50020 and
EN 50281-1-1