EasyManua.ls Logo

Pramac MP 34-2 - Page 11

Pramac MP 34-2
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IENI
5-6
TROUBLE SHOOTING:
THE PUMP DOES NOT SUPPLY A SUFFICIENT RATE OF FLOW
AIR INFILTRATION DURING SUCTION YES
CHECK THE COUPLING TIGHTENING
AND INSPECT THE SUCTION PIPE
NO
THE SUCTION PIPE DIAMETER IS NOT
LARGE ENOUGH
YES REPLACE THE SUCTION PIPE
NO
CHECK OTHER POSSIBLE CAUSES
MENTIONED IN THE PREVIOUS
SECTION
YES
FOLLOW THE CORRESPONDING
INSTRUCTIONS
NO
TAKE THE MOTOR PUMP TO THE
NEAREST SERVICE CENTER
TROUBLE SHOOTING:
PUMP PRESSURE IS NOT SUFFICIENT
LIQUID VISCOSITY IS HIGHER THAN
THE ONE WHICH IS RECOMMENDED
FOR THE LIQUIDS TO ENTER THE
PUMP
YES
PUMP A LIQUID HAVING A LOWER
VISCOSITY
NO
LOW PUMP R.P.M. YES
INCREASE MOTOR PUMP R.P.M.
DO NOT EXCEED THE MAX.
RECOMMENDED R.P.M.
NO
CHECK OTHER POSSIBLE CAUSES
MENTIONED IN THE PREVIOUS
SECTION
YES
FOLLOW THE CORRESPONDING
INSTRUCTIONS
NO
TAKE THE MOTOR PUMP TO THE
NEAREST SERVICE CENTER
TROUBLE SHOOTING:
THE ENGINE DOES NOT START:
IS THERE ANY FUEL IN THE TANK? NO FILL TANK
YES
IS THE FUEL TANK TAP OPEN?
NO OPEN
YES
IS THERE AIR IN THE FEEDING
CIRCUIT? ⊗⊗
YES ELIMINATE
NO
IS THE CHOKE ON? ⊗⊗⊗
NO ACTION
YES
IS THERE OIL IN THE ENGINE? NO FILL UP
YES
IS THE SPARK PLUG CONNECTED?
⊗⊗⊗
NO CONNECT
YES
TAKE THE MOTOR PUMP TO THE
NEAREST SERVICE CENTRE
ONLY WHEN FORESEEN
⊗⊗ ONLY FOR DIESEL ENGINE
⊗⊗⊗ ONLY FOR EXPLOSION ENGINE
IENI
6-6
TECHNICAL DETAILS AND SPECIFICATIONS:
Model MP34-2 MP36-2 MP56-3 MP66-3
Engine Honda GX160 Honda GX120 Honda GX160 Honda GX240
Max power (kW) 4,0 2,9 4,0 5,9
n (rpm) 3600 3600 3600 3600
Displacement (cc) 163 118 163 242
Starting
Self-winding recoil
start
Self-winding recoil
start
Self-winding recoil
start
Self-winding recoil
start
Total head (m) 30 30 26 27
Max delivery (l/min) 700 600 930 1340
Suction diameter 2” 2” 3” 3”
Delivery diameter 2” 2” 3” 3”
Tank capacity (l) 3,6 2,5 3,6 6
Dry weight (kg) 30 30 26 27