Wastegate spring removal and installation
1. Remove the PW66 WASTEGATE from the inlet pipe.
USE CAUTION AS THE WASTEGATE MAY STILL BE VERY HOT!
2. W
ARNING! THE WASTEGATE CAN TOP IS UNDER HIGH SPRING TENSION. USE
SAFETY GOGGLES AND REMOVE WITH CARE. Using a 4mm hex key, loosen and remove the
wastegate v-band clamp. The use of a press or vise may be used to hold down the wastegate can top
while loosening the clamp. If using a press or vise for disassembly, use a cloth or micro fiber rag to
protect the surface finish from scratches. Remove the clamp and cap slowly, using care to secure the
spring top plate and spring/springs upon removal.