Lists key functionalities and benefits of the PAC1 access controller.
Details electrical, environmental, and physical characteristics of the PAC1 unit.
Defines the ground connection for the power supply.
Specifies the power input terminals for AC or DC voltage.
Identifies the data line for connecting to an encoder.
Output for driving an LED to show door unlocked status.
Electric Latch Control relay for locking/release mechanism.
Input for monitoring door status via a normally closed switch.
Door Open Too Long alarm relay output.
Egress input for releasing the door, can be N.O. or N.C.
Data input/output for optional event logger or PACDL.
Ensures the door relocks after being opened, preventing tailgating.
Warns if the door remains open for an excessive period after access.
Detects and signals if the door is opened without valid access.
Locks out all codes for 1 minute after 5 incorrect entries.
Allows selection of multiple user codes for access.
Wiring diagram for connecting VR43 and VR62 keypads to the PAC1.
Wiring diagram for connecting PSK16 and PRE keypads to the PAC1.
Wiring diagram for PSC16/PSR16 keypads and prox readers.
Wiring diagram for connecting PSE-IL keypads to the PAC1.
Wiring diagram for connecting PRO2410 prox readers to the PAC1.
Wiring connection for DC electric locks, including diode recommendation.
Wiring connection for AC electric locks, including VDR.
Output for connecting to external devices like motorised doors.
Wiring for the egress switch to allow exit.
Wiring for the door contact switch to monitor door status.
Explains how to enter and use program mode with a keypad.
Describes audible feedback for successful/unsuccessful programming.
Method to program using keypads lacking an 'E' key.
Sequence to clear all stored user access codes.
Sequence to restore the PAC1 to its original factory settings.
Step-by-step guide for configuring essential PAC1 features.
Configure the automatic relocking feature; factory default is enabled.
Select the type of egress switch (N.O. or N.C., level or edge triggered).
Set the ELC relay to Normally Open (fail secure) or Normally Closed (fail safe).
Set the duration the ELC relay remains active, from 1 to 255 seconds.
Enable the door input for 'Door Open Too Long' and 'Door Forced Open' functions.
Set the time limit for the door to be open before a DOTL alarm.
Configure the detection of doors opened without valid access.
Configure the lockout period after multiple invalid code entries.
Select operation mode: Normal, Any Two Codes, Code 000/001+Other, Sequential.
Set the time window for entering sequential codes in High Security Mode.
Enable/disable using any code to relock the door after toggle unlock.
Enable compatibility with PACDL systems, with reduced user codes and features.
Provides a quick reference for programming installation options.