MI15-24B / Page 7 / 14
QF7720956 rev3>
• For power cables passing through a corrugated protective sheath, it is recommended to apply two
layers of fabric tape every 3 to 6 inches minimum to prevent the cable from coming out of the
corrugated protective sheath (Figure 14). The ends of the corrugated protective sheath should be
covered with fabric tape (figure 15).
Figure 14: Two layers of fabric tape applied every 3
to 6 inches to prevent the cable from coming out of
the corrugated protective sheath.
Figure 15:
The ends of the corrugated protective
sheath should be covered with fabric tape.
• Stud terminal nuts properly tightened. Use a nut with nylon insert to replace a similar nut where
applicable. Protect ring cable lugs against tightening force by placing a flat washer between nut and
ring cable lug.
When required, use fasteners that secure cables while preventing rubbing