6
• The LED is solid whenever the charge cycle has terminated and the internal
circuitry has determined the batteries to be fully charged.
• The LED will blink during the nishing stage of the charge cycle. After the
completion of the charge cycle, the LED will remain steady during the oat-
maintenance stage.
LED indicators scrolling from rst LED up to the LED,
then the sequence repeats.
Special fault code. Call PCS Technical Support (615.471.5300)
LED indicators scrolling back and forth. First LED to
LED—then from LED back down to rst LED, then the sequence repeats.
This indicates the unit is connected through Bluetooth.
Your system provides an equalization stage every 30 days while plugged in.
• If the charger is normally disconnected from A/C after completing charge, equalization
can be accomplished by plugging back into A/C whenever this stage is desired. Battery
manufacturers recommend that equalization is done once a month in order to further
reduce sulfation on the lead plates of a battery, which helps promote longer battery
life.
• Note: During this process the LEDs will go through their normal routine ( LEDs
counting up for % of charge along with the illuminated LED Battery Type) and
then the LED and Battery Type LED will blink until the unit returns to
the maintenance mode and a steady LED and steady Battery Type
LED.