fast-blo
wn fuse
Frequency response: (40~200)Hz
Display: average value response (RMS of sine wave)
2-3-5.
Range Accuracy Resolution
200 ±(0.8%+5d) 0.1
2k 1
20k 10
200k 100
2M
±(0.8%+3d)
1k
20M ±(1.0%+25d) 10k
200M ±(5.0%+30d) 100k
Open circuit voltage: less than 0.7V
Overload protection: 250V DC and AC peak value.
Note: At Range 200, short-circuit the test lead to test the wire
resistance, and then subtract it from the real measurement.
WARNING: DO NOT input any voltage at resistance
range for safety!
2-3-6.(C)
Range Accuracy Resolution
2nF ±(2.5%+20d) 1pF
20nF ±(2.5%+20d) 10pF
200nF ±(2.5%+20d) 100pF
2uF ±(2.5%+20d) 1nF
20uF ±(5.0%+10d) 10nF
• Overload protection: 36V DC or AC peak value
WARNING: DO NOT input any voltage at this range for
safety!