3. June 2024 © Copyright 2024, PROCEQ SA 38
7 Technical Specification
Measurement Principle
Stepped-frequency continuous-wave (SFCW) GPR
Regulations compliance CE, IC, FCC, ETSI-EN RSS-220 and RoHS
Connection
Wi-Fi (802.11n) to display unit
USB-C for Wi-Fi restricted areas (GP8100 & GP8800)
Warranty 2 years
Operating Temperature 5°C to 40°C / 40°F to 105°F
Storage Temperature -10°C to +60°C / 15°F to 140°F
Relative humidity
up to 85 %, non condensing
Protection against water
and dust
IP 54
Depth accuracy ± 5 mm / 0.2 in (upon direct dielectric calibration!)
Distance accuracy
Distance accuracy
between objects (like
rebars)
<2% error on distance
GP8000 or GP8100: 4 cm / 1.6 in
GP8800: 3cm / 1.2 in
Note: for objects' depth at 5 cm / 2 in