Gentile cliente,
La ringraziamo per aver scelto DF400 con portata di 400 litri/ora, filtro esterno affidabile e
silenzioso per nano acquari di aqua dolce, marina, acquari erborati e nano shrimp. Le consigliamo
di leggere attentamente queste istruzioni per il funzionamento corretto e sicuro dell’apparecchio.
Dopo aver aperto la confezione controllare che le parti elencate siano incluse.
1) Tappo di chiusura con O-ring
2) Ghiere stringitubo (4 pz)
3) Corpo pompa con O-ring e clips di bloccaggio
4) Rotore
5) Coperchio rotore
6) Tubo aria
7) Cartucce filtranti (3 pz)
8) Spugna filtrante
9) Elementi filtranti in plastica atossica
10) Corpo filtro
11) Aspirazione - tubo a L
12) Aspirazione - raccordo verticale
13) Aspirazione - prefiltro
14) Mandata - tubo a L
15) Mandata - giunto a L
16) Mandata - diffusore a spruzzo
17) Ventose (4 pz)
18) Tubi flessibili (2 pz)
Norme di sicurezza
Tutti gli apparecchi elettrici utilizzati devono essere collegati ad un relé differenziale salvavita con
soglia 30 mA. Verificare che la tensione stampata sull’etichetta del prodotto corrisponda a quella
della vostra rete di alimentazione. Questo apparecchio è per esclusivo uso interno con una
temperatura dell’acqua non superiore a 35°C. Non usare l’apparecchio con liquidi corrosivi.
Prima di collegare l’apparecchio alla rete, verificare che il prodotto o il cavo non risultino in alcun
modo danneggiati. Il cavo di alimentazione non può essere sostituito o riparato. In caso di
danneggiamento sostituire l’intera unità. L’apparecchio non deve funzionare senz’acqua per
evitare danneggiamenti al motore. Non usare l’apparecchio per scopi diversi da quelli indicati.
Scollegare il cavo dall’alimentazione prima di maneggiarlo. Non maneggiare il cavo o la spina di
connessione con mani bagnate. In caso la spina di connessione o la presa di corrente fossero
bagnate disinserire l’interruttore generale prima di scollegarlo. Tenere l’apparecchio lontano da
fonti di calore. Per evitare che accidentali gocciolamenti bagnino la spina o la presa di corrente si
consiglia di creare con il cavo un’ansa al di sotto del livello della presa (Fig A). Non sollevare
l’apparecchio usando il cavo di alimentazione Questo apparecchio può essere utilizzato da
bambini di età superiore agli 8 anni e da persone con ridotte capacità fisiche, mentali o sensoriali
o prive di esperienza e conoscenza, solo se sono controllati o se sono istruiti all’uso
dell’apparecchio in modo sicuro e in grado di comprenderne i rischi. I bambini non devono giocare
con l’apparecchio. Pulizia e manutenzione non devono essere eseguite dai bambini senza
supervisione. Tenere l’apparecchio e il cavo fuori della portata dei bambini di 8 anni.
Norme per la sicurezza elettrica in classe di protezione II
Il filtro in classe di protezione II è costruito con cavo bipolare, doppio isolamento e non è previsto il
collegamento di terra.
Question and Answer IconNeed help?

Do you have a question about the prodac DF400 and is the answer not in the manual?

Overview

The PRODAC DF400 is a reliable and silent external filter designed for nano aquariums, including freshwater, reef, planted, and nano shrimp tanks. It has a flow rate of 400 liters/hour.

Parts List:

  1. Cap with O-ring
  2. Hose lock nuts (4 pcs)
  3. Pump head with O-ring and locking clips
  4. Impeller
  5. Impeller cover
  6. Airline tubing
  7. Filter cartridge (3 pcs)
  8. Filter sponge
  9. Non-toxic plastic bio-balls
  10. Filter body
  11. Intake tube - L shaped fitting
  12. Intake tube - vertical fitting
  13. Intake tube - strainer
  14. Outlet tube - L shaped fitting
  15. Outlet tube - L-shaped connector
  16. Outlet tube - spray-bar
  17. Suction cups (4 pcs)
  18. Flexible hoses (2 pcs)

Safety Regulations:

All electrical appliances must be connected to an emergency cut-off switch set to 30 mA. Users should verify that the mains voltage matches the product label. This appliance is for indoor use only, with water temperatures not exceeding 35°C. It must not be used with corrosive or abrasive liquids. Before connecting to the mains, check for any damage to the cable or appliance. The power cable cannot be replaced or repaired; if damaged, the entire unit must be replaced. The appliance should not be operated without water to prevent impeller damage. It should only be used for its intended purpose. Disconnect the power cable before handling. Do not handle the power cable or plug with wet hands. If the plug or power socket becomes wet, shut off the mains before disconnecting. Keep the appliance away from heat sources. To prevent water from dripping onto the plug or socket, it is recommended to form a drip loop with the cable below the level of the power socket (Fig A). Do not lift the appliance by its cable.

This appliance can be used by children aged 8 and above, and by persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, provided they are supervised or have been instructed on safe use and understand the associated hazards. Children should not play with the appliance. Cleaning and maintenance should not be performed by children unless they are over 8 and supervised. Keep the appliance and its cord out of reach of children under 8 years.

Electrical Safety Standards for Class II Appliances:

The Class II filter features a twin cable with double insulation and does not require an earthing conductor.

Installation:

Before any aquarium maintenance, disconnect all electrical equipment, both inside and outside the tank. To access the filter media, open the locking clips on the filter body and lift off the pump head (Fig.B). Remove the filter media, rinse them thoroughly under running water, and place them back in their original position (the filter sponge with the hole facing upwards). Do not use soap or detergents.

Assemble the intake and outlet tube fittings separately, connect them to the flexible hoses using the hose lock nuts, and secure the hoses to the inside wall of the tank with the suction cups. The outlet unit can be configured with either the L-shaped fitting or the spray-bar, depending on preference. The spray-bar can be installed at or below water level to adjust oxygenation. Connect the flexible hoses to the intake (IN) and outlet (OUT) units on the pump head, securing them with the hose lock nuts.

Place the pump head onto the filter body, ensuring the locking clips are fully open, then close the clips (Fig. C) to secure it. Verify that it is properly seated. Unscrew the cap of the filter body, fill it with water, and screw the cap back on tightly. Check all connections for watertightness before plugging the filter into the mains. For initial priming, the DF400 must be placed on a flat surface, in a vertical position, next to the aquarium.

Maintenance:

Before any aquarium maintenance, disconnect all electrical equipment, both inside and outside the tank. Open the locking clips and lift off the pump head without disconnecting the flexible hoses. To preserve bacterial colonies, wash or replace only a portion of the filter media at a time. To clean the impeller, remove the two screws from the impeller cover with a Phillips screwdriver, extract the impeller, and rinse it under warm running water. It is recommended to clean the impeller every three months and replace it annually. If necessary, clear any deposits from the intake and outlet units and flexible hoses using a small brush. Do not use soap or detergents. Reassemble the unit in reverse order and restart the filter following the "Installation" instructions.

Warranty:

This appliance is guaranteed for 24 months from the date of purchase against defects in materials and workmanship. The warranty does not cover defects caused by tampering, negligence, or improper use. Consumable parts that require regular replacement for normal maintenance or are subject to wear are excluded. The warranty certificate must be completed by the retailer and accompany the appliance, along with the sales receipt or fiscal receipt, in case of return.

Correct Disposal of This Product (Waste Electrical & Electronic Equipment):

(Applicable in the European Union and other European countries with separate collection systems) The symbol on the product or its literature indicates that it should not be disposed of with other household waste at the end of its life. To prevent environmental or health harm from uncontrolled waste disposal, separate this product from other waste types and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact their retailer or local government office for information on environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of their purchase contract. This product should not be mixed with other commercial waste for disposal.

DF700, DF800, DF1200, DF1400 Series (Additional Information):

These external filters are available with different flow rates and tank capacities:

  • DF700: 750 liters/hour for 100-200 liter tanks
  • DF800: 850 liters/hour for 250-350 liter tanks
  • DF1200: 1200 liters/hour for 350-500 liter tanks
  • DF1400: 1400 liters/hour for 600-800 liter tanks

Parts List for DF700, DF800, DF1200, DF1400:

  1. IN/OUT unit (intake and outlet unit)
  2. Pump head
  3. Filter media container cover grid
  4. Filter media containers (DF700 and DF1200: 2 pcs; DF800 and DF1400: 3 pcs)
  5. Filter wool
  6. Filter sponge
  7. CRYSTALCIL
  8. Filter body with locking clips
  9. Intake unit - U-tube
  10. Intake unit - strainer
  11. Outlet unit - U-tube
  12. Outlet unit - L-shaped fitting
  13. Outlet unit - adjustable diffuser
  14. Outlet unit - spray-bar
  15. Outlet unit - spray-bar fitting
  16. For both Intake/Outlet unit - vertical fitting
  17. Tube connectors (4 pcs)
  18. Suction cups (6 pcs)
  19. Flexible hoses (2 pcs)

Installation for DF700, DF800, DF1200, DF1400:

Before any aquarium maintenance, disconnect all electrical equipment, both inside and outside the tank. Open the locking clips on the filter body and lift off the pump head (Fig.B). Remove the cover grid and media containers. Separate the media containers by opening their locking clips with a flat-blade screwdriver or similar tool (Fig.C). Remove the pre-supplied filter media, rinse thoroughly under running water before use. Fill the empty containers with PRODAC INTERNATIONAL filter media: CRYSTALCIL and CLAROCAR (not supplied). Rinse these thoroughly before use. Do not use soap or detergent. Caution: Do not overfill the containers to avoid clogging the flow-through pipe. For optimal filtration, place the media in the containers from bottom to top in the following order:

  • DF700 and DF1200: CRYSTALCIL, sponge, wool
  • DF800 and DF1400: CRYSTALCIL, CLAROCAR, sponge, wool If the aquarium is new, add NITRIDAC (not supplied) directly into the filter to activate bacteria. If the aquarium is already set up, add AQUASANA (not supplied) directly into the tank to maintain biological water balance. Close the containers with the locking clips, slide them along the groove into the filter body (Fig. D). Cover the last container with the grid, aligning the hole for the UV light. Connect the strainer to the intake U-tube (Fig. E). If necessary, insert the vertical fitting to the U-tube before the strainer (Fig. F) using a tube connector (Fig.G). Secure the tube to the inside wall of the tank with suction cups. Caution: The strainer must be installed below the minimum water level. Connect the L-shaped fitting to the outlet U-tube using tube connectors, and insert the adjustable diffuser (Fig.H). Alternatively, assemble the spray-bar and its fitting to the desired length and connect to the L-shaped fitting (Fig.I). Caution: The spray-bar can be installed below water level or just above the surface, depending on the desired oxygenation and surface movement. Secure the tube to the tank wall with suction cups. Cut the flexible hoses to the appropriate length to connect them to the intake and outlet U-tubes, ensuring no kinks. Shorten if necessary. Open the closing lever of the IN/OUT unit and lift it off the pump head (Fig.J). Connect the flexible hoses to the intake (IN) and outlet (OUT) units, securing them with the locking nuts (Fig.K). Insert the unit into the pump head and lock it with the lever. Fill the filter body with ¼ water, place the pump head onto the filter body, and lock it with the clips. Caution: The UV lamp cover must fit exactly into the hole of the first media container. Check that the pump head's sealing gasket is properly seated and clean. Place the filter in the desired location. For optimal functioning, the distance between the water surface and the filter base should not exceed 180 cm. Manually operate the priming pump until water reaches the outlet tube (Fig.L). Check all connections for watertightness, then connect the pump head to the mains. After about 30 minutes, when there is no air inside the filter, adjust the flow rate by moving the lever on the IN/OUT unit (Fig.M). Press the lighting button of the UV lamp (Fig. N); an indicator light (Fig. O) will show that the UV lamp is on. All "DF series" external filters must be installed on a flat surface and in an upright position before priming.

Maintenance for DF700, DF800, DF1200, DF1400:

Before any aquarium maintenance, disconnect all electrical equipment, both inside and outside the tank. Pull out the intake and outlet unit (IN/OUT) without disconnecting the flexible hoses. Unlock the pump head by opening the locking clips on the filter body and lift it off. Remove each media container and wash the filter media. Replace wool, sponge, and CLAROCAR every three months, and CRYSTALCIL every six months. To avoid destroying bacterial colonies, wash and replace only a part of the filter media at a time. To clean the impeller, unscrew the two screws from the impeller cover with a Phillips screwdriver (Fig.P), remove the impeller, and rinse it under warm water. It is recommended to clean the impeller every three months and replace it annually. If necessary, clear any deposits from the intake and outlet units and flexible hoses using a small brush. Do not use soap or detergents. Reassemble the unit in reverse order and connect the filter to the mains as described under "Installation".

UV Lamp Replacement:

If the UV lamp indicator light is off, even if the lighting button is on (Fig.Q), the UV lamp is not working and must be replaced. Pull out the pump head, unscrew the black plastic cover of the UV lamp with a Phillips screwdriver (Fig. R). Pull the quartz tube upwards, remove the lamps, and replace them. Reassemble the unit in reverse order. Caution: When reassembling the UV lamp unit, the quartz tube does not fully fit into its housing because it forms a small vacuum that ensures watertightness. Push down the tube cover strongly to fit it tightly. It is suggested to perform this operation with two people (Fig.S).

prodac DF400 Specifications

General IconGeneral
Brandprodac
ModelDF400
CategoryWater Filtration Systems
LanguageEnglish