5
Installation Before Transfer Box continued
Attach the green ground wire to the ground screw on side of box.
(See visual references on pages 11-13). Make sure the wire colors
match up adjacent to each other. Torque down set screws and
ground nut to secure connections.
8. Double check all connections and make sure they are secure.
9. Remove the two screws on contactor where marked L1, L2, etc.
Next remove the top plastic plate with markings. Examine inside
ensuring there are no loose plastic pieces inside the contactor. If
so, remove and re-install cover with two screws. (See visual
references on pages 11-13).
Do not over tighten screws as this could break cover tabs.
Caution: If you break off a tab and do not remove it, this may
stop the contactor from working and allow 240 volts in the RV.
10. Secure cable ends by tightening down strain reliefs over the
input and output wires. Do not over tighten as this could bit
through the insulation and cause a short.
11. Set time delay jumper on the circuit board. The factory setting
is for 15 seconds. Remove jumper to set for 136 seconds
(02:16). See Features Section on time delay to determine
which to use. (See visual references on pages 11-13).
12. Plug in remote display and cable. (This cable is not a phone
cable, but rather a data cable).
NEVER PLUG IN DISPLAY WHILE RV POWER IS ON.
13. Attach EMS lid with the six black machine screws provided.
14. Mount the EMS control box.
15. Installation is complete. Next, plug in and follow operating
instructions.