156
Vess A Class NVR Storage Appliance Promise Technology
disable The write policy of the writeback logical drives are not changed
irrespective of the availability of BBU or UPS.
hostcacheushing= Subsystems only. To enable or disable host cache ushing.
For high availability products only.
enable
disable
forcedreadahead= Enables or disables forced read ahead caching.
enable
disable
commonwwnn= Enables or disables common WWNN. For high availability products only.
enable All controllers report one common WWNN.
disable Each controller reports its own WWNN.
alua= Subsystems only. Enables or disables asymmetric logical unit access.
Enabling ALUA will enable LUN afnity automatically.
enable
disable
-t <condition type> Species the type of condition to clear.
Valid only when the command action is “clear.
-l Displays the id of the controller on whose serial port the CLI is running.
-v Verbose mode. Used with the -a list option.
Examples
ctrl
ctrl -v
ctrl -l
ctrl -a mod -i 1 -s “alias=ctrl1, coercion=enable”