OPERATING
INSTRUCTIONS
It
is
advisable
to
read
through
the
Instructions
first
before
attempting
to
operate
the
scale.
Bypassing
certain
procedures
may
give
incorrect
readings.
PREPARING
YOUR
SCALE
1.
Before
attempting
to
use
your
Propert
Glass
Body
Analysis
scale,
remove
all
packaging.
2.
Then
open
the
battery
compartment
cover
on
the
base
of
the
scale
&
insert
the
2
Lithium
batteries
(CR2032)
provided.
Ensure
the
batteries
are
placed
inside
the
compartment
with
the
positive
(+)
sides
facing
up.
Replace
the
compartment
cover.
3.
Ensure
you
remove
shoes,
socks
or
stockings
before
using
the
scale
as
this
may
affect
body
fat
and
water
content
readings
Power
on
for
a
body
Scroll
up,
Scroll
down,
analysis
reading,
change
unit
change
unit
menu
select,
confirm
measure
measure
OPERATING
MODES
The
Propert
Glass
Body
Analysis
Scale
has
2
operating
modes
for
-
e
Weighing
only
and...
e
Weighing
to
compute
your
body
fat,
water,
muscle,
bone
percentage
and
BMI
(“Personal
data
must
be
set
for
this
function.
This
scale
is
able
to
store
data
including
gender,
height
and
age
for
10
people).
Weighing
Only
1.
Place
the
Scale
on
a
hard
&
even
surface.
Use
on
carpet
or
uneven
surfaces
may
cause
inaccuracies.
2.
To
turn
the
scale
on
for
weighing
only,
tap
on
the
scale
platform
with
your
foot.
3.
The
scale
briefly
displays
‘8888’
before
it
nm
s
‘zeroes
Indicating
it
is
in
weighing
mode
Uu
and
ready
for
use.
4,
At
this
point,
select
the
unit
measure
(kilograms,
@)
stones
pounds
or
pounds)
by
pressing
the
conversion
button
underneath
the
scale
5.
Then
gently
step
onto
the
scale.
When
standing
on
your
scale,
make
sure
your
feet
are
placed
evenly,
your
weight
is
distributed
evenly
between
your
feet
and
you
stand
perfectly
still.
Movement,
leaning
backward
or
forward
or
not
standing
evenly
on
your
scale,
will
affect
the
accuracy
of
the
weight
displayed.
6.
Your
weight
value
will
be
shown
on
the
display
7.
If
left
idle,
the
scale
automatically
turns
off
Entering
personal
data
(the
digits
PO
-
P9
represent
each
of
10
users).
1.
Turn
the
scale
on
by
pressing
the
‘SET’
button
2.
A
personal
user
number
at
the
bottom
left
corner
of
the
screen
flashes.
3.
Press
either
of
the
arrow
buttons
to
select
a
number
of
your
choice.
4,
The
digits
PO
-
P9
represent
each
of
10
users.
Remember
this
number
for
future
reference.
You
might
want
‘PO’
for
yourself,
your
partner
might
like
‘P1’,
your
son
‘P2’,
daughter
‘P3’
and
so
forth.
Press
the
‘SET’
button
to
‘lock’
it
in
5.
A
gender
symbol
flashes.
Press
either
of
the
arrow
buttons
to
make
your
selection,
then
press
the
‘SET’
button
to
‘lock’
it
in.
T
6.
The
number
for
years
flash.
Press
either
of
the
arrow
buttons
to
scroll
up
or
down
to
enter
your
age,
then
press
the
‘SET’
button
to
‘lock’
it
in
7.
Height
measurements
then
flash.
Press
either
of
the
arrow
buttons
to
scroll
up
or
down
to
enter
your
height,
then
press
the
‘SET’
button
to
‘lock’
it
in.
(If
‘Kg’
was
chosen
as
the
medsurement
unit,
then
your
height
will
be
shown
in
terms
of
‘cm’.
If
‘stone
pounds’
or
just
‘bounds’
were
chosen,
then
height
would
display
in
feet
and
inches).
8.
The
programming
of
personal
data
is
now
completed.
The
scale
shows
4
dotted
lines,
then
‘zeroes’,
indicating
it
is
ready
for
use.
You
may
step
on
it
for
a
body
analysis
reading...Or
9.
You
may
continue
to
enter
data
for
another
user
or
modify
data
by
repeating
Steps
1-7.
Remember
that
each
other
person
will
have
a
different
identifying
user
number.
Toggle
between:-
Male
symbol
located
on
the
left
above
the
personal
number.
Female
symbol
located
on
the
right
above
the
personal
number.
Weighing
to
compute
your
body
fat,
water,
muscle,
bone
percentage
and
BMI
1.
Tap
the
scale
to
turn
it
on
2.
Press
either
of
the
arrow
buttons
to
find
the
number
you
chose
as
your
personal
user
number.
There
is
no
need
to
press
‘Set’
once
you
have
located
the
number.
Wait
until
the
scale
shows
‘zero’
indicating
it
is
ready
for
use.
4,
Gently
step
onto
the
scale.
>
>
“Note
that
your
bare
feet
must
be
centred
over
and
on
the
electrodes
(vertical
metal
strips)
|
for
an
effective
reading.
l
=
“These
electrodes
allow
a
very
low
electrical
impulse
(which
cannot
be
felt)
to
pass
through
the
body.
The
scale
applies
Bioelectrical
Impedance
Analysis
(BIA)
to
compute
the
measurements.
Your
weight
is
then
shown.
5.
Continue
to
stand
still.
The
scale
will
flash
4
x
‘0’
while
computation
h
oO oO
is
taking
place.
Pa
6.
Your
body
fat,
water,
muscle,
bone
percentages
and
BMI
will
appear
on
the
screen
and
display
2
times
sequentially
co
?
Ig"
to
I
oo
JTI
a”
"a
A
l
f
LI
fat
=
A
a
da
>
h
=
3
7.
The
scale
automatically
turns
off
after
that.
LAST
RESULT
RECALL
FUNCTION
After
measuring
weight,
fat,
water,
muscle,
bone
and
BMI,
the
scale
automatically
stores
the
data
into
memory
l.
To
view
these
results,
turn
the
scale
on
and
select
your
personal
user
number
(No
need
to
press
‘SET’
after
that).
The
scale
will
display
your
last
recorded
measurements.
2.
The
scale
then
‘zeroes’
ready
for
use
again.
3.
When
you
measure
yourself
again,
the
scale
will
record
the
new
results
and
this
will
replace
the old
data
OVERLOADING
If
the
scale
is
overloaded
(over
150kg
/
23st
/
330lb),
‘EEEE’
appears
on
the
display.
Remove
the
weight
immediately
or
damage
to
the
scale
may
occur.
LOW
BATTERY
INDICATOR
When
‘LO’
displays
on
the
screen,
the
batteries
must
be
replaced.
Remember,
always
use
fresh,
good
quality
lithium
batteries.
ERROR
INDICATION
‘Err2’
indicates
that
body
analysis
has
been
unsuccessful,
or
quite
often,
that
body
fat
content
is
less
than
5%
or
more
than
50%
SPECIFICATIONS
6mm
thick
tempered
glass
platform
Capacity
-
150kg
/
23st
/
330lb
Weight
graduation
-
0.1kg
/
1/4lb
/
0.2lb
Body
Fat
percentage
range
5
-
50%;
Graduation
0.1%
Water
percentage
range
20
-
70%;
Graduation
0.1%
Muscle
range
15
-
75%;
Graduation
0.1%
Bone
weight
range
1
-
11.7Kg
/
2.2
-
25.8lb
Age
range
10
-
80
years
Height
range
100
-
225cm
/
3'3"-
7'3":
Graduation
lcm
/
1"
Battery
-
2
x
CR2032
batteries
(included)