DC VOLTAGE
Range Resolution Accuracy
200mV 100uV
2000mV 1mV
20V 10mV
200V 100mV
±0.8%+3d
500V 1V ±(1.0%+3d)
OVERLOAD PROTECTION: 220V rms AC for
200mV range and 500V DC or 500V rms for all
ranges.
AC VOLTAGE
Range Resolution Accuracy
200V 100mV
500V 1V
±1.2%+5d
RESPONSE: Average responding, calibrated in rms
of a sine wave.
FREQUENCY RANGE: 40Hz 400Hz
OVERLOAD PROTECTION: 500V DC or 500V rms
for all ranges.