INSTALLATION GUIDE
Keypad Features
6148PL2
Fixed-Word
6150PL2
Fixed-Word
6160PL2
2-Line Alpha
Backlit Display NO YES (See Note 1) YES (See Note 1)
Dedicated Function Keys NO YES YES
Built-in Sounder Piezo Piezo Speaker
Notes 1. Permanent display backlighting is an option on some controls (see the control's instructions for details).
GENERAL INFORMATION WIRING AND INSTALLATION
The 6148PL2, 6150PL2, and 6160PL2 are addressable
Remote Keypads designed for use with the Protection One
250P1 control panel. Addresses are set via the keypad keys
(no DIP switches).
The keys on the keypads are continuously backlit for
convenience.
KEYPAD DISPLAYS AND LEDS
The keypads have the following display features:
Model
Fixed
Word
Display
2-line
Alpha
Display
2-digit
Zone
Identifier
Custom
Zone
Descriptors
6148PL2 X X
6150PL2 X X
6160PL2 X X
The following table shows the LEDs and their functions:
LED Function
Red Lights when the system is armed in any mode
Green Lights when the system is "ready" to be armed.
SPECIAL FUNCTION KEYS
The keypads also feature function keys. These keys may be
programmed for panic alarms or other special functions
such as macros. See the control's instructions for details.
The 6148PL2 uses the key pairs only.
6150PL2&6160PL2 6148PL2
A ([1] & [*]) [1] & [*]
B ([*] & [#]) [*] & [#]
C ([3] & [#]) [3] & [#]
DNONE
The keypads can be surface mounted directly to a drywall, or to
a single- or double-gang electrical box.
1.
Remove the case back
by pushing down two "snaps."
See diagram below.
2.
Route wiring from the control panel
through the
opening in the case back.
3.
Mount the case back
to a wall or electrical box.
4.
Wire directly from the keypad’s terminal block
to the
terminal block on the control board. Wire functions are
marked next to terminals. Labels are as follows: DI Data
In to Control Panel, - Ground, + Aux. Power Plus, DO Data
Out of Control Panel. See the control panel’s Installation
Instructions for more complete details.
5.
Re-attach the keypad
to its case back.
ARMED
READY
1
2
3
654
897
0
*
#
OFF
AWAY STAY
MAX TEST BYPASS
INSTANT
CODE CHIME
READY
REMOVE CASE BACK BY PUSHING IN THE 2 SNAPS
ALONG KEYPAD'S BOTTOM EDGE AND PULLING THE CASE APART.
Function keys must be held down for at
least 2 seconds to activate an alarm, key
pairs activate immediately.