Proton Products SL mini and SLR mini Series Speed and Length Gauges Instruction Manual - issue 1s
Configuration by input parameters:
This interface may be configured by writing to the following input parameters:
Input parameters
DW
Bit
Comment
Unit
Range/Remark
Default
12
Logic input(new format;DW12.15=1)
0
Logic input 1 function
1=Length hold
0
1
2
3
Logic input 1 polarity
0=Active low
0
4
Logic input 2 function
1=Length hold
1
5
6
7
Logic input 2 polarity
0=Active low
0
8
Logic input 3 function
4=Reset
4
9
10
11
Logic input 3 polarity
0=Active low
0
12
Direction setting (available
only when no logic input
for direction)
0=Count up
1=Count down
0
13~
14
Not used
15
Must be 1
1=New format logic inputs
DW
Bit
Comment
Unit
Range/Remark
Default
14
Length offset
1=0.1m{ft}{yds}{inch}
-3000.0~3000.0m{ft}{yds}{inch}
0