5.39 ENABLE EXPANDER OUTPUT MODULES [650]
Up to 3 output modules (ROX, 16 relay outputs) can be installed on the V2 GSM. Each
ROX that is connected need to be enabled in this function.
Press the [ or ] keys to scroll to
‘ENABLE EXP OUTPUT MODULES’
or enter ‘650’.
Press B or T to select the output
module that is to be enabled or enter
the function shortcut number (see
below).
Press t
Press B or T to choose between
Yes or No or select the number:
0 = No = Default
1 = Yes
Press t
Shortcut Function Numbers:
651: Enable EXP output module:0 653: Enable EXP output module:2
652: Enable EXP output module:1
5.40 PGM 1-4 OUTPUT FUNCTIONS [660]
The 4 onboard outputs can be programmed for either:
Keypad/Remote Latched: These will enable the user to trigger outputs 1-4 by pressing
for 2 seconds the dedicated keys 1 to 4.
Keypad/Remote Pulsed: These will enable the user to trigger outputs 1-4 by pressing for
2 seconds the dedicated keys 1 to 4, or to activate them remotely by calling the V2 and
using the user voice menu. The time of the pulse is programmable in option 680, PGM
Output Timers.
Follow Input: Used in conjunction with ‘PGM output timers’ (Function 680), the output will
activate when a chosen input is activated.
Follow GSM Fault: Output activates when there is a GSM fault on the system.
Follow Low Battery: Output activates when there is 11.5v low battery detection on the
system.
Follow Expander Tamper: Output activates if there is an expander tamper activated
either on the remote input expander or the remote output expander.
Acknowledge Pulse: Output pulses for 1 sec when an acknowledgement is received
after an alarm call to the user.
No Call Acknowledge: Output activates when no acknowledgement is received after an
alarm call to the user.
CLIP Pulse: Output activates for 1 sec when the V2 GSM recognises a telephone number
being dialled without V2 answering the call.