V2 GSM Installation Manual
Pyronix Ltd Page: 31
5.41 PGM 1-4 OUTPUT TIMERS [680]
This function is used in conjunction with function 660 and any outputs that are
programmed as either ‘follow input’ or a pulsed output (the V2 GSM onboard outputs only,
function not available the ROX inputs).
Press the [ or ] keys to scroll to
‘PGM OUTPUT TIMERS’ or enter
‘680’.
Press B or T to select the PGM
number enter the function shortcut
number (see below).
Press t
Use the B or T to select the Input
number or the output timer.
Inputs: 1-14 (default 1)
Output timer:
0 = Disabled = Default
1 = 5 seconds
2 = 15 seconds
3 = 60 seconds
4 = 1 hour
5 = 3 hours
6 = 12 hours
7 = 24 hours
8 = 1 week
9 = 2 weeks
press t
Shortcut Function Numbers:
681: PGM#1 timer/follow input 683: PGM#3 timer/follow input
682: PGM#2 timer/follow input 684: PGM#4 timer/follow input