7.8 CONNECTING AN OUTPUT EXPANDER (PCX-ROX16R)
Up to 3 output expanders may be installed on the V2 GSM. Each output expander must
be individually addressed using the dip switches:
Address
Switch
1 2 4 8
00 OFF OFF OFF OFF
01 ON OFF OFF OFF
02 OFF ON OFF OFF
Output Map:
Onboard Outputs: PGM1-4 onboard
1
st
Output Expander: PGM 1-16 expander
2
nd
Output Expander: PGM 17-32 expander
3
rd
Output Expander: PGM 33-48 expander