Standby Mode
Pressing “Warm” or “Cool” then “Jets 2” will turn
off all spa functions temporarily. This is helpful
when changing a filter.
Press any button to exit Standby mode.
Jets 1
Press the “Jets 1” button once to turn pump 1 on,
again to switch to high-speed. Pressing for a third
time turns pump 1 off. If left running, the low
speed turns off after 2 hours and the high speed
turns off after 15 minutes.
The low-speed of pump 1 runs when the blower or
any other pump is on. It may also activate for at
least 2 minutes every 30 minutes to detect the spa
temperature (polling) and then to heat to the set
temperature if needed, depending upon mode.
When the low speed turns on automatically, it
cannot be deactivated from the panel; however, the
high speed may be started.
Jets 2
Press the “Jets 2” button once to turn pump 2 on,
again to turn on high-speed. Pressing once more,
turns off pump 2. If left running, the pump will
turn off after 15 minutes.
Jets 3
Option only available on Ultra XLP model spas.
Press the “Jets 3” button once to turn pump 3 on,
again to turn on high-speed. Pressing once more,
turns off pump 3. If left running, the pump will
turn off after 15 minutes.
Blower
Press the “Blower” button to turn on, twice to turn
on low speed, three times to turn on medium speed
and a fourth time to turn on high-speed. Pressing
once more will turn the blower off.
If left on, the blower will automatically turn off
after 15 minutes.
Temperature Display Inversion
Press the “Invert” button to change the numbers in
the display to read upside down. Another press
returns the display to its normal right-side-up
display.
Light
Press the “Light” button to turn the spa light on
and off, and to shift between dim and bright
settings if your light is dimmable. On dim, the
LCD will show center circle plus one quarter of
the light beams. Half of the light beams will show
on medium brightness, and all of the light beams
will show on bright.
LED Lighting
If LED lighting is installed press the “Light”
button to start the unit. To change colors or
modes, press the “Light” button off and on to cycle
the unit. If the light or LED unit is left on, it will
automatically turn off after 4 hours.
OPTIC
Button is not used for this model.
Preset Filter Cycles
On all systems, the pump and the ozone generator
will run during filtration. At the start of each filter
cycle, the blower will run on highest speed for 30
seconds to clean out the air channels. The low-
speed of pump 2 will run for 5 minutes.
There are two filter cycles per day. The start/end
times of each cycle are programmable. To
program, set time as instructed above, then press
“Mode/Prog” to advance to the next setting (or to
exit after the last setting). The default filter cycles
are as follows:
The first filter cycle is automatically activated at
8:00 AM and operates the pump until 10:00 AM.
The filter 1 indicator icon will light when filter 1 is
running.
The second filter cycle is automatically activated
at 8:00 PM and operates the pump until 10:00 PM.
The filter 2 indicator icon will light when filter 2 is
running.
Optional Filter Cycle Programming
You are not required to set filter cycles; however,
it is an option available to you. To change the filter
cycle settings:
Press “Time” “Mode/Prog” “Mode/Prog”
“Mode/Prog” within 3 seconds. You will see the
“SET FILTER 1” and a flashing “START TIME”
icon appear on the display.
Press “Up” or “Down” to choose the filter start
time hour. Enter the hour by pressing
“Mode/Prog”. Press “Up” or “Down” to choose the
filter start time minutes. Each press changes the
start time by 5 minutes.
Enter the minutes by pressing “Mode/Prog.”
Press “Mode/Prog” to see the “SET FILTER 1”
and a flashing “END TIME” icon. Adjust the time
as done above.
Press “Mode/Prog” to see the “SET FILTER 2”
(PM cycle) and a flashing “START TIME” icon.
Proceed as above.
Press “Mode/Prog” to see “SET FILTER 2” and a
flashing “END TIME” icon. Adjust the time as
done above.
Pressing “Mode/Prog” will enter the new filter
cycle times into the system and display the current
water temperature.
Pressing “Time” at any time during this
programming sequence will save the values
entered up to that point and exit programming.
If you would like to select continuous filtration, set
the filter 1 start and end times to be the exact same
time.
6