BES X installation manual Electrical specifications
P/N: 400288005; Rev: L, 09/21 13
2 Electrical specifications
Provide AC power to the system components via an electrical subpanel that is dedicated solely to the BES X
system. The subpanel must have a neutral bus and a separate insulated third-wire isolated ground that is
connected at the main service panel only.
Provide AC power to other system components as described for each component, including the installation
of distribution boxes and running power cables to the final location of the other system components.
Test the electrical ground before installing any components and periodically thereafter to ensure the BES X
system remains properly grounded.
IMPORTANT: Only QubicaAMF-supplied devices should be plugged into the outlets dedicated for QubicaAMF
components.
ALWAYS FOLLOW YOUR LOCAL CODES FOR WIRE STANDARDS AND WIRING CIRCUITS.
PLEASE REFER TO THE āBES X PRE-INSTALLATION MANUALā FOR FURTHER DETAILS.