BES X system configurations BES X installation manual
20 P/N: 400288005; Rev: L, 09/21
3.2.2 EasyKey Lane and EasyKey Twin console
In this configuration, the following devices are installed on each pair of lanes:
the camera (Q-Vision or T/M-Vision);
the pinspotter interface;
other optional LCOM devices (Bumper interface, Q-FOUL, TMR, etc.);
one 4HD/5HD-HUB;
one 4HD/5HD-CPU;
the overhead monitors (i.e. two overhead monitors).
For the console, there are two options:
EasyKey Lane: two EasyKey console on two different pedestals (please refer to Table T.10.027);
EasyKey Twin: two EasyKey console on the same pedestal (please refer to Table T.10.028).
The camera, pinspotter interface and the other optional LCOM devices are connected to the 4HD/5HD-HUB
via the LCOM cable (Refer to section LCOM Line for further information).
The L1 port of the 4HD/5HD-CPU is connected to the L1 port of the 4HD/5HD-HUB via a network cable.
Each overhead monitor is connected to the corresponding port of the 4HD/5HD-CPU unit with a HDMI cable.
If the monitors do not support commands via the HDMI, a serial communication cable (P/N: 288401007)
must be installed between the overhead monitors and the 4HD/5HD-CPU in order to be controlled directly
from a Conqueror X computer.
The EasyKey console on the ODD lane is connected to the L3 port of the 4HD/5HD-HUB through a network
cable (grey cable).
The EasyKey console on the EVEN lane is connected to the L4 port of the 4HD/5HD-HUB through a network
cable (yellow cable).
The differences between the two console configurations are in the quantity of pedestals and the quantity of
speakers installed, because each pedestal has only one speaker. Due to this fact, the connection cable for the
speaker is slightly different between the two situations.
Each console must be connected to ground. Please refer to the section Suggested ground connection of the
BES X Pre-Installation Manual for further information.