BES X system configurations BES X installation manual
28 P/N: 400288005; Rev: L, 09/21
3.3.4 SuperTouch Lane console
In this configuration, the following devices are installed on each pair of lanes:
the camera (Q-Vision or T/M-Vision);
the pinspotter interface;
other optional LCOM devices (Bumper interface, Q-FOUL, TMR, etc.);
one 4HD/5HD-HUB;
one 4HD/5HD-CPU;
the overhead monitors (i.e. two overhead monitors);
two SuperTouch consoles.
The camera, pinspotter interface and the other optional LCOM devices are connected to the 4HD/5HD-HUB
via the LCOM cable (Refer to section LCOM Line for further information).
The L1 port of the 4HD/5HD-CPU is connected to the L1 port of the 4HD/5HD-HUB via a network cable.
Each overhead monitor is connected to the corresponding port of the 4HD/5HD-CPU unit with a HDMI cable.
If the monitors do not support commands via the HDMI, a serial communication cable (P/N: 288401007)
must be installed between the overhead monitors and the 4HD/5HD-CPU in order to be controlled directly
from a Conqueror X computer.
The SuperTouch console version 2 (or higher) on the odd lane is connected to:
L3 port of the 4HD/5HD-HUB through a network cable (grey cable);
The SuperTouch console version 2 (or higher) on the even lane is connected to:
L4 port of the 4HD/5HD-HUB through a network cable (yellow cable);
Or
The SuperTouch console (PN: 288150024) on the odd lane is connected to:
L3 port of the 4HD-HUB through a network cable (grey cable);
P1 port of the 4HD-HUB through a network cable (red cable): connect the network cable on the 4HD-
HUB side to the 288401035 cable adapter then the 288401035 cable adapter to the P1 connector of
the 4HD-HUB unit.
The SuperTouch console (PN: 288150024) on the even lane is connected to:
L4 port of the 4HD-HUB through a network cable (yellow cable);
P1 port of the 4HD-HUB through a network cable (blue cable): connect the network cable on the
4HD-HUB side to the 288401035 cable adapter, then connect the 288401035 cable adapter to the P1
connector of the 4HD-HUB unit.
In the case that an existing BES X bowling center, already equipped with SuperTouch consoles (P/N
288150024), purchases EDGE String pinspotters, the existing 4HD-HUB units MUST be replaced with the 5HD-
HUB P/N: 288250025-01 or P/N: 288250025-02 units and the “5HD-HUB to first gen. SuperTouch cable
adapter” (P/N: 288401054). Please refer to T.10.075 for further information.
Each console must be connected to ground. Please refer to the section Suggested ground connection of the
BES X Pre-Installation Manual for further information.