BES X installation manual Scoring network
P/N: 400288005; Rev: L, 09/21 61
5.2.3 Centers with up to 12 lanes, MMS, TCS, Q-COM and single channel video server.
Three 8-port network switches will be supplied by QubicaAMF for this configuration.
The connections for the main scoring network switch are:
• 1 port for the home-run cable;
• 1 port for the slave scoring network switch;
• 1 port for the MMS and Q-DAC switch.
The connections for the slave scoring network switch are:
• 1 port for the main scoring network switch;
• 1 port for the single channel video server;
• 6 ports for 4HD/5HD-HUB units.
The connections for the MMS and Q-DAC switch are:
• 1 port for the main scoring network switch;
• 7 ports for MMS and Q-DAC units.
The 4HD/5HD-HUB units must be connected to the slave scoring network switch via standard patch network
cables. Refer to T.20.096 for the correct patch cables’ lengths.
The single channel video server, if present, must be connected to the slave scoring network switch using a
Cat.5e solid network cable.
The slave scoring network switch must be connected to the main scoring network switch using the provided
network cable.
The second network card of the Conqueror X server must be connected to the main scoring network switch
using a Cat.5e solid network cable.
The MMS and the Q-DAC units must be connected to the MMS and Q-DAC switch.
The MMS and Q-DAC switch must be connected to the main scoring network switch using the provided
network cable.
This configuration is described in the Table T.20.093.