BES X Installation Manual, Rev.9, Jun 2018 System first start-up
P/N: 400288005 125
19. Within five minutes (from the “system halted” message) each pair of lanes will restart
automatically, or each pair of lanes can be restarted manually by unplugging and plug back the
power cord of the 4HD/5HD-HUB.
20. After this restart the Reinizialization process will continue.
21. When the Reinizialization process will finish, the system will boot up.
22. If on the lane monitors appear the error number 203, the problem could be the wrong pinsetter
parameters.
23. In any case (whether if the lane stops in error 203 or if the lane boot correctly) set up the correct
pinsetter parameter in ConquerorPRO.
24. In ConquerorPRO go to the ConquerorPRO main menu: Setup / Technical Setup / Pinsetter and
Camera
25. In the window select the destination lane” choose the first lane where you must load the
parameters and press OK.
26. Press the Defaults button in order to load the standard values.
27. Once the default values have been loaded, press the Send button to load them on to the 4HD/5HD-
CPU.
28. When prompted to Reset the Lane Control Box press NO.
29. Now press the Copy to button in order to load the values on all the lanes that have the same
pinsetter and interface type.