System boot up sequence BES X Installation Manual, Rev.9, Jun 2018
138
138 P/N: 400288005
LCOM Test:
Error 212 The 4HD/5HD-CPU is not able to get a reply from the main L-COM device (1)
Runtime error:
All the following errors are scoring software errors and have to be reported to QubicaAMF
Error 900 Internal Error (1)
Error 901 NexOS Version Error (1)
Error 902 Internal Error on score initialize (1)
Error 903 Internal Error (1)
Error 904 Internal Error on video initialize (1)
Error 905 Internal Error on score initialize (1)
Error 906 Internal Error on score malloc (1)
Error 907 Internal Error on score exception (1)
(1) Manually restart the 4HD/5HD-HUB.
(2) The 4HD-CPU is either a wrong unit (for MMS only) or it is faulty. The unit has to be replaced.
(3) The SuperTouch console has not been detected during the startup of the VTNT.
(4) Upload programs to the lanes.
(5) This error can appear when the SuperTouch has been replaced or when the console has been
detected but it did not enter in Run state. Reinitialize to the lanes.
(6) Manually restart the 4HD/5HD-HUB. If the problem persist try to upload programs to the lanes. In
the case that the problem has not been solved please refer to the “6.3 – Solving problems on the
LCOM line” procedure in the “BES X installation manual”.
(7) The T-Vision / Q-Vision board is not able to work with the camera. Usually the problem is in the
wiring between the board and the camera. If the problem persist contact QubicaAMF authorized
support.
(8) The lane configuration needs an F-Box (enhanced pinsetter interface) but it is impossible to
communicate with it. In the case that the F-Box is not present, check the Pinsetter Parameters.
(9) The microprocessor on the F-Box as an old version loaded on it and the lane cannot be configured
to handle the strike signal.
(10) Internal errors that should be reported to QubicaAMF. To restart the program manually restart the
4HD/5HD-HUB.
(11) Check pinsetter and camera parameters of both the lanes of the pair.