21
3. (Pulse speed adjustment)
Select setting item "CYC" by pressing “Dec(-)” or “Inc(+)” button, then press “Enter
key and the initial value of “CYC” will blink. Use “Dec(-)” or “Inc(+)” button to
adjust the pulse speed (cycle).
(Note: In the interface of adjusting the value, return to the initial value "5"by pressing
“Dec(-)” and Inc(+)” buttons simultaneously for about 1 second.)
Press “Enter” button, the adjusted value stops blinking, now the value has been set.
- The smaller the set value, the faster the pulse speed.
Cycle speed (CYC)
0 ~ 30
Initial value; 5
4. (Operation point setup)
Select setting item "TGP" by pressing “Dec(-)” or “Inc(+)” button, then press “Enter”
key and the initial value of “TGP” will blink. Use “Dec(-)” or “Inc(+)”button to
adjust the operation point.
(Note: In the interface of adjusting the value, return to the initial value "30" by
pressing “Dec(-)” and Inc(+)” buttons simultaneously for about 1 second.)
Press “Enter” button, the adjusted value stops blinking, now the value has been set.
- Sets the throttle trigger position at which the A.B.S. function is performed.The
number is the % display with the full brake position made 100.
Operation point (TGP)
0 ~ 100
Initial value; 30
5. (Cycle duty ratio setup)
Select setting item "DTY" by pressing “Dec(-)” or “Inc(+)” button,then press“Enter”
key and the initial value of DTY” will blink. Use “Dec(-)” or “Inc(+)” button to
adjust the duty ratio.