EasyManua.ls Logo

Radwin 5000 HPMP - Page 467

Radwin 5000 HPMP
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RADWIN5000HPMPUserManual Release3.5.70 C48
PrivateMIBParameters
winlink1000OduAirHssAssociatedC
UTableEntry
N/A AssociatedEthernetHSSClientsTableEntry.
ReleantforEthernetHSSMastersonly.INDEX{
winlink1000OduAirHssAssociatedCUIndex}
winlink1000OduAirHssAssociatedC
UIndex
RO AssociatedEthernetHSSClientsTableIndex.
ReleantforEthernetHSSMastersonly.
winlink1000OduAirHssAssociatedC
UDescription
RO HoldsAssociatedEthernetHSSClients
Descriptionincompressformat:IPDelay
CompatibilityEthernetSpeedEthernetRxrate
IPv6
winlink1000OduAirHssSyncStatusEt
h
RO EthernetHSSClientSynchronizationLevel
winlink1000OduAirHssEthVLANTag RW EthernetHSSVLanTag:Theleastsignificate
decimaldigitistheVLanPriority(06)andthe
restofthedigitsrepresentsVLanID(24094)
winlink1000OduAirHssHSMIPAddre
ss
RO HSMsIPaddress.RelevantforHSCsynchronized
overEthernet.
winlink1000OduAirHssDelayToHSM RO DelayinmicrosecondstoHSM.RelevantforHSC
synchronizedoverEthernet.
winlink1000OduAirHssSyncAcquisiti
onSeconds
RW Accumulatedquantityofsecondsinclock
acquisitionwhileconnectedtocurrentHSM
winlink1000OduAirHssHSMIPv6Add
ress
RO HSMsIPv6address.RelevantforHSC
synchronizedoverEthernet.
winlink1000OduAirLockRemote 1.3.6.1.4.1.4458.1000.1.5.4
1
Integer RW Thisparameterenableslockingthelinkwitha
specificODU.Thefollowingvaluescanbeset:
Unlock(default)‐TheODUisnotlockedona
specificremoteODU.Unlockcanonlybe
performedwhenthelinkisnotconnected.
Lock‐TheODUislockedonaspecificremote
ODU.Lockcan
onlybeperformedwhenthelink
isactive.
winlink1000OduAirAntennaGain 1.3.6.1.4.1.4458.1000.1.5.4
2
Integer RW CurrentAntennaGainin0.1dBire solution.User
definedvalueforexternalantenna.Legal
range:
MinAntennaGain<AntennaGain<MaxAntennaG
ain.
winlink1000OduAirFeederLoss 1.3.6.1.4.1.4458.1000.1.5.4
3
Integer RW CurrentFeederLossin0.1dBmresolution.User
definedvalueforexternalantenna.
winlink1000OduAirMaxAntennaGai
n
1.3.6.1.4.1.4458.1000.1.5.4
4
Integer RO MaximumallowedAntennaGainin0.1dBi
resolution.
winlink1000OduAirMinAntennaGai
n
1.3.6.1.4.1.4458.1000.1.5.4
5
Integer RO MinimumallowedAntennaGainin0.1dBi
resolution.
winlink1000OduAirMaxEIRP 1.3.6.1.4.1.4458.1000.1.5.4
6
Integer RO MaximumEIRPvalueasdefinedbyregulationin
0.1dBmresolution.
winlink1000OduAirAntennaGainCo
nfigSupport
1.3.6.1.4.1.4458.1000.1.5.4
7
Integer RO AntennaGainConfigurabilityoptionsare
productspecific:supportednotsupported.
winlink1000OduAirAntennaType 1.3.6.1.4.1.4458.1000.1.5.4
8
Integer RW ExternalAntennaType:MonopolarorBipolar.
winlink1000OduAirRssBalance 1.3.6.1.4.1.4458.1000.1.5.4
9
Integer RO RSSbalance .RelationbetweenRSSinradio1
andRSSinradio2.‐2:Radio2RSSismuch
strongerthanRadio1RSS.‐1:Radio2RSSis
strongerthanRadio1RSS.‐0:Radio2RSSis
equaltoRadio1RSS.1:Radio1
RSSisstronger
thanRadio2RSS.2:Radio1RSSismuch
strongerthanRadio2RSS.
winlink1000OduAirTotalTxPower 1.3.6.1.4.1.4458.1000.1.5.5
0
Integer RO TotalTransmitPowerindBm.Thisisanominal
valueWhiletheactualtransmitpowerincludes
additionalattenuation.
TableC3:PrivateMIBParameters‐HSU(Sheet10of33)
Name OID Type
Access
Description

Table of Contents