RADWIN5000HPMPUserManual Release3.5.70 C61
PrivateMIBParameters
winlink1000IduSrvEthThroughput RO CurrentavailableEthernetservicethroughputin
bps.
winlink1000IduSrvEthMaxInfoRate RW Holdsthemaximumbandwidth(kbps)tobe
allocatedforEthernetservice.Valueofzero
meansthatEthernetserviceworksasbest
effort.Themaximumvalueisproductspecific.
Refertotheusermanual.
winlink1000IduSrvAvailableTrunksT
1
RO AbitmapdescribingtheTDMtrunksthatcanbe
openedunderT1configuration.Thevalues
takeintoaccounttheIDUhardware
configurationtheairrateandtheinstallation
range.
winlink1000IduEthernetIfTable N/A IDUEthernetInterfacetable.
winlink1000IduEthernetIfEntry N/A IDUEthernetInterfacetableentry.INDEX{
winlink1000IduEthernetIfIndex}
winlink1000IduEthernetIfIndex RO IfIndexcorrespondingtothisInterface.
winlink1000IduEthernetIfAddress RO IDUMACaddress.
winlink1000IduEthernetNumOfLan
Ports
RO NumberofLANinterfacesintheIDU.
winlink1000IduEthernetNumOfSfpP
orts
RO Thenumbe rofSFPinterfacesintheIDU.
winlink1000IduEthernetSfpProperti
es
RO SFPvenforproperties:VendorNamePNand
Revision.
winlink1000IduEthernetGbeSuppor
ted
SupportedGigabitEthernetinIDU.
winlink1000IduEthernetOduInError
s
RO Thenumbe rofinboundpacketsthatcontained
errorspreventingthemfrombeingdeliverable
toahigherlayerprotocol.
winlink1000IduBridgeTpAging RW Timeoutinsecondsforaging.Notethatforthis
parametertobeeffectivetheODUmustbe
configuredtoHUBmode.Achangeiseffective
immediately.
winlink1000IduTdmTxClockAvailStat
es
RO AvailablestatesoftheTDMTransmitClock
Controleachinputstatusisrepresentedbya
bit.Whenthestateisavailablethebitvalueis
1.Whenthestateisunavailablethebitvalue
is0.Theavailablestatesare:bit2=
Transparentbit3=LocalLoopTimedbit
4=
RemoteLoopTimedbit5=LocalInternalbit6
=RemoteInternal
winlink1000IduTdmT xClockDesiredS
tate
RW RequiredstateoftheTDMTransmitClock
Control.Achangeiseffectiveafterreactivation
oftheTDMservice.
winlink1000IduTdmTxClockActualSt
ate
RO ActualstateoftheTDMTransmitClockControl.
winlink1000IduTdmMasterClockAva
ilOptions
RO AvailableoptionsoftheTDMMasterClock
Controleachinputstatusisrepresentedbya
bit.Whentheoptionisavailablethebitvalue
is1.Whentheoptionisunavai lablethebit
valueis0.Theavailableoptionsare:bit2=
Automaticbit3=Tr unk#1bit4
=Trunk#2bit
5=Trunk#3bit6=Trunk#4Whennooptions
areavailablethereturnedvalueis:1
winlink1000IduTdmMasterClockDes
ired
RW RequiredTDMMasterClock.Achangeis
effectiveafterreactivationoftheTDMservice.
winlink1000IduTdmMasterClockAct
ual
RO ActualTr unkusedforTDMMasterClock.
winlink1000IduTdmConfigTable N/A IDUTDMLinksConfigurationtable.
TableC3:PrivateMIBParameters‐HSU(Sheet23of33)
Name OID Type
Access
Description