EM510 SENSe Subsystem:FUNCtion
4065.7763.32-01.00 5.80
. . [:ON] <sensor_function> {,<sensor_function>}
Switch on of one or several sensor functions.
Error message:
If CONCurrent = OFF, an error -108, "Parameter not allowed" will be generated for ten or
more parameters.
Parameters:
<sensor_function> is one of the following strings:
"VOLTage:AC" switch on level measurement
"FREQuency:OFFSet" switch on offset measurement
Note:
The offset measurement works only with signals whose signal energy may vary but must not disappear
completely. At QAM or 100 % AM-modulated signals, the offset measurement cannot provide correct
values.
Note:
With SW option EM510IM (ITU Measurement) installed, apart from level and offset the measurement
functions AM modulation index , FM frequency deviation, PM phase deviation and band width
measurement are also available.
"AM" switch on AM modulation index measurement
"AM:POSitive" switch on AM positive modulation index measurement
"AM:NEGative" switch on AM negative modulation index measurement
"FM" switch on FM frequency deviation measurement
"FM:POSitive" switch on FM positive frequency deviation measurement
"FM:NEGative" switch on FM negative frequency deviation measurement
"PM" switch on PM phase deviation measurement
"BANDwidth" switch on bandwidth measurement
*RST state:
"VOLTage:AC"
Example:
FUNCtion "VOLT:AC", "FREQ:OFFS"