CALibration Subsystem EM510
5.21 4065.7763.32-01.00
5.3.5 CALibration Subsystem
. : ROSCillator[:DATA] <numeric_value> [MINimum|MAXimum|UP|DOWN]
Changing the calibration value (D/A-converter value) for setting the exact OCXO reference frequency.
Parameter:
<numeric_value> 0 ... 4095
*RST state:
none
default state (not calibrated)
2048
Example:
CALibration:ROSCillator UP
. : ROSCillator[:DATA]? [MINimum|MAXimum]
Query about the calibration value (D/A-converter value) for setting the exact OCXO reference
frequency.
Parameter:
none query about the current calibration value
MINimum|MAXimum query about the lowest/highest calibration value
Result:
Calibration value or D/A-converter value for setting the exact OCXO reference frequency.
Example:
CALibration:ROSCillator? MAX -> 4095