EM510 MEMory Subsystem
4065.7763.32-01.00 5.44
. :CONTents? <name>|RX
Query about contents of memory location.
Parameters:
<name> MEM0 to MEM9999 | RX | CURRENT
Result:
Depending on the setting by the command FORMat:MEMory either an ASCII data set or a binary data
set is output:
The ASCII data set has the following structure:
<F>,<THR>,<DEM>,<BW>,<ANT>,<ATT>,<ATTA>,<SQUC>,<AFC>,<ACT>
<F> frequency (see SENS:FREQ:CW?)
<THR> squelch threshold (see OUTP:SQU:THR?)
<DEM> demodulation type (see SENS:DEM?)
<BW> bandwidth (see SENS:BWID?)
<ANT> antenna number (see ROUT:CLOS:STAT?)
<ATT> attenuator (see INP:ATT?)
<ATTA> attenuator auto (see INP:ATT:AUTO?)
<SQUC> squelch function (see OUTP:SQU:STAT?)
<AFC> AFC function (see (SENS:FREQ:CW:AFC?)
<ACT> set/reset for scan (1/0)
The binary data set is transferred as a <Definite Length Block> and has to be interpreted
according to the above-mentioned format.
Notes:
During a query about the receiver data set (RX) the parameter <ACT> is not defined and has to be
ignored.
When trying to read out an empty memory location the error message "MEMORY EMPTY" is
generated.
Example:
MEMory:CONTents? MEM1 -> 801000,34,AM,9000,#14(@1),1,0,1,0,1