R&S ESU Instrument Functions
Analyzer Mode
4.230 Operating Manual 1302.6163.12 - 03
The PowerClass element is structered as follows:
<PowerClass Index="n">
<StartPower Unit="dBm" InclusiveFlag="true" Value="StartPowerValue"/>
<StopPower Unit="dBm" InclusiveFlag="false" Value="StopPowerValue"/>
<DefaultLimitFailMode>Limit Fail Mode</DefaultLimitFailMode>
<Range Index="n">
<!-- For contents of the Range node see Table 4-5 -->
<!-- Define up to twenty Range nodes -->
</Range>
...
</PowerClass>
The Range element is structered as follows:
<Range Index="n">
<Name="Name">
<ChannelType>Channel Type</Channel Type>
<WeightingFilter>
<Type>FilterType</Type>
<RollOffFactor>Factor</RollOffFactor>
<Bandwith>Bandwidth</Bandwidth>
</WeightingFilter>
<FrequencyRange>
<Start>RangeStart</Start>
<Stop>RangeStop</Stop>
</FrequencyRange>
<Limit>
<Start Unit="Unit" Value="Value"/>
<Stop Unit="Unit" Value="Value"/>
</Limit>
<Limit>
<Start Unit="Unit" Value="Value"/>
<Stop Unit="Unit" Value="Value"/>
</Limit>
<RBW Bandwidth="Bandwidth" Type="FilterType"/>
<VBW Bandwidth="Bandwidth"/>
<Detector>Detector</Detector>
<Sweep Mode="SweepMode" Time="SweepTime"/>