Operating Manual 1302.6163.12 - 03 6.47
R&S ESU Remote Control – Description of Commands
CALCulate Subsystem
CALCulate<1|2>:MARKer<1...4>:Y:PERCent 0 to100%
This command positions the selected marker in the selected window to the given probability. If marker
2, 3 or 4 is selected and used as a delta marker, it is switched to marker mode.
Example: "CALC1:MARK:Y:PERC 95PCT"
'Positions marker 1 in screen A to a 'probability of 95%.
Characteristics: *RST value: -
SCPI: device-specific
Mode: A
CALCulate<1|2>:MARKer<1...4>:MAXimum[:PEAK]
This command positions the specified marker to the current maximum value of the corresponding
trace. The corresponding marker is activated first or switched to the marker mode.
Example: "CALC:MARK2:MAX"
'Positions marker 2 in screen A to the maximum value of 'the trace.
Characteristics: *RST value: -
SCPI: device-specific
Mode: R, A
This command is an event and therefore has no *RST value and no query.
CALCulate<1|2>:MARKer<1...4>:MAXimum:NEXT
This command positions the specified marker to the next smaller maximum value of the corresponding
trace.
Example: "CALC:MARK2:MAX:NEXT"
'Positions marker 2 in screen A to the next 'lower maximum value.
Characteristics: *RST value: -
SCPI: device-specific
Mode: R, A
This command is an event and therefore has no *RST value and no query.
The command is only available with the CCDF measurement switched on.
The associated level value can be determined with the CALC:MARK:X? command.
If no maximum value is found on the trace (level spacing to adjacent values < peak
excursion), an execution error (error code: -200) is produced.
If no next smaller maximum value is found on the trace (level spacing to adjacent
values < peak excursion), an execution error (error code: -200) is produced.