Operating Manual 1302.6163.12 - 03 6.163
R&S ESU Remote Control – Description of Commands
SENSe Subsystem
[SENSe<1|2>:]CORRection:TRANsducer:VIEW ON | OFF
This command switches on the display of the active transducer factor or set. Prior to this command,
the command SENS:CORR:TRAN:SEL must be sent.
This command is available from firmware version 1.40 or higher.
Example: "CORR:TRAN:SEL 'FACTOR1'"
"CORR:TRAN:VIEW ON"
Characteristics: *RST value: OFF
SCPI: device-specific
Mode: R, A
[SENSe<1|2>:]CORRection:TRANsducer:ADJust:RLEVel[:STATe] ON | OFF
This command switches the automatic adjustment of the reference level to the selected transducer
factor on or off. Prior to this command, the command SENS:CORR:TRAN:SEL must be sent.
Example: "CORR:TRAN:SEL 'FACTOR1'"
"CORR"CORR:TRAN:ADJ:RLEV ON"
Characteristics: *RST value: OFF
SCPI: device-specific
Mode: R, A
[SENSe<1|2>:]CORRection:TSET:SELect <name>
This command selects the transducer set designated by <name>. If <name> does not exist yet, a new
set is created.
This command must be sent prior to the subsequent commands for modifying/activating
transducersets.
Parameter: <name>::= name of the transducer set in string data form with a maximum of 8
characters.
Example: "CORR:TSET:SEL 'SET1'"
Characteristics: *RST value: -
SCPI: device-specific
Mode: R, A
[SENSe<1|2>:]CORRection:TSET:UNIT <string>
This command defines the unit of the selected transducer sets. When assigning transducer factors to
the set, only factors which are compatible to the selected unit, i.e. factors with the same unit or the unit
dB, are allowed. Prior to this command, the command SENS:CORR:TSET:SEL must be sent.
Parameter: <string>::= 'DB' | 'DBM' | 'DBUV' | 'DBUV/M' | 'DBUA' | 'DBUA/M'' | DBPW' | 'DBPT'
Example: "CORR:TSET:SEL 'SET1'"
"CORR:TSET:UNIT 'DBUV'"
Characteristics: *RST value: 'DB'
SCPI: device-specific
Mode: R, A