Operating Manual 1302.6163.12 - 03 6.319
R&S ESU Remote Control – Description of Commands
Differences in GPIB Behavior between the FSP and the FSE Families of Instruments
R&S
ESU
FSE [SENSe<1|2>:]BANDwidth|BWIDth[:RESolution]:
MODE:FFT
ON | OFF old command that is still
supported, but has been
replaced on the
R&S ESU by
[SENSe<1|2>:
]BANDwidth|BWIDth[:
RESolution]:TYPE
R&S
ESU
FSE [SENSe<1|2>:]BANDwidth|BWIDth[:RESolution]:
RATio
0.0001 to 1
R&S
ESU
[SENSe<1|2>:]BANDwidth|BWIDth[:RESolution]:
TYPE
NORMal | FFT | CFILter |
RRC
new function for
R&S ESU
R&S
ESU
[SENSe<1|2>:]BANDwidth|BWIDth:VIDeo:TYPE LINear | LOGarithmic new function for
R&S ESU
R&S
ESU
FSE [SENSe<1|2>:]CORRection:COLLect[:ACQuire] THRough | OPEN
FSE [SENSe<1|2>:]CORRection:CVL:BAND A|Q|U|V|E|W|F|D|G|Y|J not available for
R&S ESU and FSET
FSE [SENSe<1|2>:]CORRection:CVL:BIAS <numeric_value> not available for
R&S ESU and FSET
FSE [SENSe<1|2>:]CORRection:CVL:CATalog? not available for
R&S ESU and FSET
FSE [SENSe<1|2>:]CORRection:CVL:CLEar not available for
R&S ESU and FSET
FSE [SENSe<1|2>:]CORRection:CVL:COMMent <string> not available for
R&S ESU and FSET
FSE [SENSe<1|2>:]CORRection:CVL:DATA <freq>,<level> to not available for
R&S ESU and FSET
FSE [SENSe<1|2>:]CORRection:CVL:MIXer <string> not available for
R&S ESU and FSET
FSE [SENSe<1|2>:]CORRection:CVL:PORTs 2 | 3 not available for
R&S ESU and FSET
FSE [SENSe<1|2>:]CORRection:CVL:SELect <file_name> not available for
R&S ESU and FSET
FSE [SENSe<1|2>:]CORRection:CVL:SNUMber <string> not available for
R&S ESU and FSET
FSE [SENSe<1|2>:]CORRection:CVL:TYPE ODD | EVEN | EODD not available for
R&S ESU and FSET
FSE/
FSIQ
[SENSe<1|2>:]CORRection:LOSS:INPut[:
MAGNitude]
<numeric_value> not available for
R&S ESU
R&S
ESU
FSE [SENSe<1|2>:]CORRection:METHod TRANsmission |
REFLexion
R&S
ESU
FSE [SENSe<1|2>:]CORRection:RECall
FSE [SENSe<1|2>:]CORRection:RXGain:INPut[:
MAGNitude]
<numeric_value> not available for
R&S ESU, FSET and
ESIB
R&S
ESU
FSE [SENSe<1|2>:]CORRection[:STATe] ON | OFF