CALCulate<1|2>:MARKer<1...4>:FUNCtion:ZOOM <numeric_value> 6.55
CALCulate<1|2>:MARKer<1...4>:LOEXclude ON | OFF 6.46
CALCulate<1|2>:MARKer<1...4>:MAXimum:AUTO ON | OFF 6.48
CALCulate<1|2>:MARKer<1...4>:MAXimum:LEFT 6.48
CALCulate<1|2>:MARKer<1...4>:MAXimum:NEXT 6.47
CALCulate<1|2>:MARKer<1...4>:MAXimum[:PEAK] 6.47
CALCulate<1|2>:MARKer<1...4>:MAXimum:RIGHt 6.48
CALCulate<1|2>:MARKer<1...4>:MINimum:AUTO ON | OFF 6.49
CALCulate<1|2>:MARKer<1...4>:MINimum:LEFT 6.50
CALCulate<1|2>:MARKer<1...4>:MINimum:NEXT 6.49
CALCulate<1|2>:MARKer<1...4>:MINimum[:PEAK] 6.49
CALCulate<1|2>:MARKer<1...4>:MINimum:RIGHt 6.50
CALCulate<1|2>:MARKer<1...4>:PEXCursion <numeric_value> 6.50
CALCulate<1|2>:MARKer<1...4>:SCOupled[:STATe] ON | OFF 6.46
CALCulate<1|2>:MARKer<1...4>[:STATe] ON | OFF 6.42
CALCulate<1|2>:MARKer<1...4>:TRACe 1 to 3 6.42
CALCulate<1|2>:MARKer<1...4>:X 0 to MAX (frequency | sweep time) 6.42
CALCulate<1|2>:MARKer<1...4>:X:SLIMits:LEFT 0 to MAX (frequency | sweep time) 6.43
CALCulate<1|2>:MARKer<1...4>:X:SLIMits:RIGHt 0 to MAX (frequency | sweep time) 6.44
CALCulate<1|2>:MARKer<1...4>:X:SLIMits[:STATe] ON | OFF 6.43
CALCulate<1|2>:MARKer<1...4>:Y:PERCent 0 to100% 6.47
CALCulate<1|2>:MARKer<1...4>:Y? 6.46
CALCulate<1|2>:MATH[:EXPression][:DEFine] (<expr>) 6.87
CALCulate<1|2>:MATH:MODE LINear | LOGarithmic | POWer 6.88
CALCulate<1|2>:MATH:POSition -100PCT to 200PCT 6.87
CALCulate<1|2>:MATH:STATe ON | OFF 6.87
CALCulate<1|2>:PEAKsearch|PSEarch:ADD <nummeric value> 6.89
CALCulate<1|2>:PEAKsearch|PSEarch:AUTO ON | OFF 6.89
CALCulate<1|2>:PEAKsearch|PSEarch:CLEar[:IMMediate] 6.89
CALCulate<1|2>:PEAKsearch|PSEarch[:IMMediate] 6.89
CALCulate<1|2>:PEAKsearch|PSEarch:MARGin MINimum .. MAXimum 6.90
CALCulate<1|2>:PEAKsearch|PSEarch:METHod SUBRange | PEAK 6.90
CALCulate<1|2>:PEAKsearch|PSEarch:SUBRanges 1 to 500 6.90
CALCulate<1|2>:STATistics:X:MPOSition 0 … 100 6.94
CALCulate<1|2>:THReshold MINimum to MAXimum (depending on
current unit)
6.95
CALCulate<1|2>:THReshold:STATe ON | OFF 6.95
CALCulate<1|2>:TLINe<1|2> 0 to 1000s 6.96
CALCulate<1|2>:TLINe<1|2>:STATe ON | OFF 6.96
CALCulate<1|2>:UNIT:POWer DBM | V | A | W | DBPW | WATT | DBUV |
DBMV | VOLT | DBUA | AMPere | DBPT |
DBUV_M | DBUA_M
6.97
CALibration:ABORt 6.98
CALibration[:ALL]? 6.98
CALibration:RESult? 6.99
CALibration:STATe ON | OFF 6.99
DIAGnostic<1|2>:SERVice:CSOource[:POWer] <numeric_value> 6.102
DIAGnostic<1|2>:SERVice:HWINfo? 6.103
DIAGnostic<1|2>:SERVice:INPut:PULSed:PRATe 10 kHz | 62.5 kHz | 1 MHz | 128 MHz | 640
MHz
6.100
DIAGnostic<1|2>:SERVice:INPut:PULSed[:STATe] ON | OFF 6.100
DIAGnostic<1|2>:SERVice:INPut:RECTangle:PRATe 5 kHz | 31.25 kHz | 50 kHz | 250 kHz | 500
kHz
6.101
DIAGnostic<1|2>:SERVice:INPut:RECTangle[:STATe] ON | OFF 6.101
DIAGnostic<1|2>:SERVice:INPut[:SELect] CALibration | RF 6.100
DIAGnostic<1|2>:SERVice:NSOurce ON | OFF 6.102
Command Parameter Page