R&S ESU Instrument Functions
Receiver Mode
4.56 Operating Manual 1302.6163.12 - 03
TDOMAIN
SCAN |
STEPPED
SCAN
The TDOMAIN SCAN and STEPPED SCAN softkeys open a submenu where exist-
ing scan tables can be edited or new ones created. Tables with the current scan set-
tings are displayed.
Remote command: --
In the SCAN TABLE the parameters for the individual subranges can be set.
ADJUST AXIS
INS BEFORE
RANGE
INS AFTER RANGE
DELETE RANGE
RANGES 1-5 | 6-10
FREQ AXIS
LIN | LOG
10dB MIN ON | OFF
RUN PRE-
SCAN+FINAL
RUN SCAN HOLD SCAN CONT AT REC
FREQ
CONT AT HOLD
STOP SCAN STOP SCAN
The TDOMAIN SCAN softkey is only available with the R&S ESU-K53 option.
Scan Start - start frequency of display range
Scan Stop - stop frequency of display range
Step Mode - selection of frequency switching mode
Start - Entry of start frequency
Stop - Entry of stop frequency
Step Size - Entry of step size
RES BW - Entry of IF bandwidth
Meas Time - Entry of measurement time
Auto Ranging - Activates the autorange function
RF Atten - Entry of a fixed RF attenuation
Preamp - Switching the preamplifier on and off
Auto Preamp - Activates the auto preamp function
RF Input - Selects the RF Input
LN Preamp - Activates Low Noise Preamplifier