826User Manual 1178.8520.02 ─ 01
//Query the peak for each range of the SEM measurement as a list.
TRAC:DATA? LIST
14.5.7 Measuring Spurious Emissions
The following commands are required to perform spurious emissions measurements.
Initializing the Measurement................................................................................. 826
Configuring a Sweep List...................................................................................... 826
Configuring the List Evaluation............................................................................. 832
Adjusting the X-Axis to the Range Definitions.......................................................835
Performing a Spurious Measurement................................................................... 835
Retrieving and Saving Settings and Results.........................................................835
Programming Example: Spurious Emissions Measurement.................................835
14.5.7.1 Initializing the Measurement
Note that with the R&S FSV/A, the spurious measurement must be initialized before
you can start configuring the sweep list or list evaluation.
INITiate<n>:SPURious....................................................................................................826
INITiate<n>:SPURious
This command initiates a Spurious Emission measurement.
Suffix:
<n>
.
14.5.7.2 Configuring a Sweep List
The following commands configure the sweep list for spurious emission measure-
ments.
The sweep list cannot be configured using remote commands during an on-going
sweep operation.
Useful commands for configuring the sweep described elsewhere:
[SENSe:]SWEep:MODE on page 793
[SENSe:]LIST:RANGe<ri>[:FREQuency]:STARt on page 797
[SENSe:]LIST:RANGe<ri>[:FREQuency]:STOP on page 798
Remote commands exclusive to spurious measurements:
[SENSe:]LIST:RANGe<ri>:BANDwidth:RESolution............................................................ 827
[SENSe:]LIST:RANGe<ri>:BANDwidth:VIDeo................................................................... 827
[SENSe:]LIST:RANGe<ri>:BREak....................................................................................827
[SENSe:]LIST:RANGe<ri>:COUNt?..................................................................................828